Answer:
c.certification
Explanation:
hope this helps!
Technician A says that the transmission hydraulic pump operates only when the vehicle is in motion. Technician B says that the transmission hydraulic pump operates when the engine is running. Which technician is correct?
Technician B is correct. The transmission hydraulic pump operates when the engine is running, regardless of whether the vehicle is in motion or not.
The best automatic transmission fluids usually claim to improve vehicle fuel mileage, but renewing the fluid will almost always do that. ( Here are some other ways to improve your miles per gallon.) Technician A states that the transmission hydraulic pump operates only when the vehicle is in motion.
While Technician B says that the transmission hydraulic pump operates when the engine is running. In this case. Technician B is correct. The transmission hydraulic pump starts operating when the engine is running, as it is driven by the engine, regardless of whether the vehicle is in motion or not.
To know more about transmission hydraulic:- https://brainly.com/question/28429219
#SPJ11
Technician B is correct.
The transmission hydraulic pump operates when the engine is running, regardless of whether the vehicle is in motion or not. The pump is responsible for supplying pressurized hydraulic fluid to the transmission to engage the gears and provide torque to the wheels.
Learn more about transmission hydraulic: https://brainly.com/question/21634180
#SPJ11
(300-23) Wiring methods and equipment installed behind panels designed to permit access (such as drop ceilings) shall be so arranged and secured to permit the removal of panels to give access to electrical equipment.(True/False)
True.
The safety of maintenance personnel and electricians who may need to access the electrical equipment behind the panels.
Properly securing the wiring methods and equipment can prevent accidental contact with live conductors, reduce the risk of electrical hazards, and facilitate safe and efficient maintenance and repair of the electrical system.
This statement is in accordance with the requirements of the National Electrical Code (NEC) Article 300.23, specifies that wiring methods and equipment installed behind panels designed to permit access (such as drop ceilings) must be arranged and secured in such a way that panels can be removed to provide access to the electrical equipment.
According to the National Electrical Code (NEC) section 300.23, wiring methods and equipment installed behind panels designed to permit access, such as drop ceilings, must be arranged and secured in a manner that allows for the removal of panels to gain access to electrical equipment.
This requirement is necessary to ensure that maintenance and repair of electrical equipment can be safely performed without causing damage to the wiring or equipment.
Electrical equipment is installed behind panels designed for access, it is important to make sure that the panels are easily removable without causing any damage to the wiring or equipment.
This is achieved by properly securing the wiring and equipment to the structure using appropriate fasteners and support systems.
Additionally, the wiring and equipment should be arranged in a way that allows for easy access to all components without the need to remove any unnecessary materials or components.
The NEC requires that wiring methods and equipment installed behind panels designed for access be arranged and secured in a manner that allows for easy removal of panels to gain access to electrical equipment.
This requirement ensures that maintenance and repair of electrical equipment can be safely performed without causing damage to the wiring or equipment.
For similar questions on Equipment
https://brainly.com/question/30003482
#SPJ11
T/F: Some of the key factors in database design are content, access, structure, archiving, and security.
The given statement "Some of the key factors in database design are content, access, structure, archiving, and security." is true because database design is the process of creating a database that is well-organized, efficient, and capable of meeting the needs of its users.
This refers to the type of data that will be stored in the database. It is important to identify the types of data, their relationships, and how they will be organized in the database. Database access involves determining who will have permission to view, edit, or delete data in the database.
This includes defining user roles and permissions, implementing access controls, and creating a user-friendly interface for accessing and manipulating data. This refers to the organization of data in the database, including the tables, fields, and relationships between them.
Learn more about database design: https://brainly.com/question/13266923
#SPJ11
(250-96(b)) Where required for the reduction of electric noise for electronic equipment, electrical continuity of metal raceway is not required, and the metal raceway can terminate to a(n) ______ nonmetallic fittings(s)or spacer on the electronic equipment.
Where required for the reduction of electric noise for electronic equipment, electrical continuity of metal raceway is not required, and the metal raceway can terminate to a nonmetallic fitting or spacer on the electronic equipment.
Hi! In accordance with NEC 250-96(b), where required for the reduction of electric noise for electronic equipment, electrical continuity of metal raceway is not required, and the metal raceway can terminate to a nonmetallic fitting(s) or spacer on the electronic equipment.
According to NEC 250-96(b), where it is necessary to reduce electric noise for electronic equipment, electrical continuity of metal raceway is not required. In such cases, the metal raceway can terminate to a nonmetallic fitting or spacer on the electronic equipment. This helps to prevent the transfer of electrical noise from the raceway to the equipment, which can interfere with its proper functioning. Nonmetallic fittings or spacers are used because they do not conduct electricity and therefore do not provide a path for the noise to travel.
Learn more about electrical continuity here;
https://brainly.com/question/12791045
#SPJ11
There shall be more than the equivalent of ____________ quarter bends 360 degrees total between pull point, for example, conduit bodies and boxes.
344.28
According to NEC section 344.28, there should not be more than the equivalent of four quarter bends (or one full 90-degree bend) in a conduit run between pull points, which can include conduit bodies and boxes. This helps to ensure that the conduit run is not excessively curved or difficult to pull wire through.
This requirement is specified in the National Electrical Code (NEC) section 344.28.
Explanation:
1. A conduit is a tube or pipe used to protect and route electrical wiring.
2. Quarter bends refer to conduit bends, with each quarter bend equal to 90 degrees.
3. The term "equivalent" means having the same value or amount.
In this context, the equivalent of four quarter bends (4 x 90 degrees) adds up to a total of 360 degrees. To comply with the NEC requirement, the conduit run should not have bends exceeding this 360-degree limit between pull points, ensuring safe and efficient installation and maintenance of the electrical system.
To learn more about National Electric Code (NEC) : brainly.com/question/31389063
#SPJ11
352-10(F)) Rigid nonmetallic conduit can be installed exposed in buildings _____.
According to the National Electric Code (NEC) section 352-10(F), rigid nonmetallic conduit can be installed exposed in buildings where it is not subject to physical damage.
However, it is important to consult with local codes and damage before installing any electrical conduit to ensure compliance and safety.Rigid nonmetallic conduit (RNC) can be installed exposed in buildings when used in accordance with the National Electrical Code (NEC) Section 352-10(F). This section states that RNC is permitted for exposed work where it is not subject to physical damage, securely fastened, and properly supported.
Learn more about damage here
https://brainly.in/question/30120812
#SPJ11
The interconnecting of timers is commonly calleda. groupingB.sequencingb. programmingd. cascading
The interconnecting of timers is commonly called cascading. Option d is answer.
Cascading is the interconnection of timers in a way that allows one timer's output to trigger the start of another timer's countdown. This technique is often used in industrial automation systems to sequence events or processes that require precise timing. By cascading timers, it is possible to create complex timing sequences that are reliable and accurate.
This approach is particularly useful for applications where multiple timers need to work together in a coordinated manner to achieve a specific goal. Cascading timers is an effective way to simplify the programming and control of complex systems, as it allows for a more modular and scalable approach to timing control.
Option d is the answer.
You can learn more about timer at
https://brainly.com/question/29850873
#SPJ11
Which syntax imports all static members of class Math? A. import java.lang.Math. B. import static java.lang.Math.C. import static java.lang.MathD. None of the above.
B. import static java.lang.Math. it is important to use import static judiciously and only when necessary, as it can make code harder to read and understand if overused.
In Java, the import static keyword is used to import static members of a class into another class without having to reference the class name each time. This allows for more concise and readable code, especially when working with static utility classes like java.lang.Math. When using import static, you can directly reference the imported static members by their name, as if they were declared in the current class. For example, you could import the PI constant from java.lang.Math and use it in your code like this: double area = radius * radius * PI;. However, it is important to use import static judiciously and only when necessary, as it can make code harder to read and understand if overused.
Learn more about import static here:
https://brainly.com/question/23091646
#SPJ11
A terminal that allows a server to enter guest orders but not settle guest accounts is called a __________ terminal.
A. cashier
B. precheck
C. "smart card"
D. self-service
A terminal that allows a server to enter guest orders but not settle guest accounts is called a A. cashier terminal. Other types of terminals that may be used in hospitality settings include precheck terminals.
A terminal is a device or computer that allows a user to access a server or network. In the context of hospitality or restaurants, a terminal can be used by servers to input guest orders into a point-of-sale (POS) system, which is typically managed by a server.
In this scenario, the terminal is restricted to only allowing servers to enter guest orders and is not authorized to settle guest accounts. This is known as a "cashier" terminal, as it is only used for inputting orders and not handling payments or cash transactions.
Other types of terminals that may be used in hospitality settings include precheck terminals, which allow guests to view menus and place orders before being seated, and self-service terminals, which allow guests to place orders and pay without assistance from a server.
Learn more about point-of-sale (POS) system here:
brainly.com/question/28198761
#SPJ11
"A terminal that allows a server to enter guest orders but not settle guest accounts is called a __________ terminal."
Your answer: A terminal that allows a server to enter guest orders but not settle guest accounts is called a B. precheck terminal.
Learn more about guest orders: https://brainly.com/question/1094377
#SPJ11
The load for house electric clothes dryers in a dwelling unit(s) shall be ________ watts (volt-amps) or the nameplate rating, whichever is larger, for each dryer served. 220.54
The load for house electric clothes dryers in a dwelling unit(s) shall be 5000 watts (volt-amps) or the nameplate rating, whichever is larger, for each dryer served.
This requirement can be found in section 220.54 of the National Electric Code. It is important to note that the nameplate rating of the dryer should always be taken into consideration when determining the load, as it may vary depending on the specific model and manufacturer.
The load for house electric clothes dryers in a dwelling unit(s) shall be 5,000 watts (volt-amps) or the nameplate rating, whichever is larger, for each dryer served. This is according to the National Electrical Code (NEC) section 220.54.
Learn more about NEC here:
brainly.com/question/28259564
#SPJ11
(310-10(H)(1)) In general, the minimum size phase, neutral or grounded conductor permitted for use in parallel is No. ___.
According to the National Electrical Code (NEC) section 310-10(H)(1), when conductors are installed in parallel is NO. 1/10 AWG.
According to the National Electrical Code (NEC) section 310-10(H)(1), when conductors are installed in parallel, they must be of the same length, have the same insulation and be terminated in the same manner at both ends.
Additionally, the minimum size of the phase, neutral or grounded conductor permitted for use in parallel is No. 1/0 AWG.
This minimum size requirement is based on the assumption that paralleling conductors will be used in large commercial or industrial applications where the electrical load is significant.
Using larger conductors helps to ensure that the load is distributed evenly across the conductors, minimizing voltage drop and improving the overall efficiency and safety of the electrical system.
Know more about the National Electrical Code (NEC)
https://brainly.com/question/20348027
#SPJ11
How is energy transferred to foods fried in deep-fat?
Foods that are fried in deep fat receive energy through conduction. The meal is uniformly cooked as a result of the hot oil heating the food's surface, which subsequently transfers heat to the centre.
Food is immersed in heated oil during the deep-frying process of cooking. The food's surface comes into touch with the heated oil when it is placed in the pan. Conduction is the method by which the heated oil conducts heat to the food's surface. Food is evenly cooked as a result of heat conduction from the surface to the centre of the food as it heats up. Conduction, which is the movement of heat through a solid or stationary fluid from a hotter location to a cooler region, is the term used to describe this heat transfer via the meal. As a result, the food receives energy from the heated oil, becoming crispy and delicious.
learn more about food's surface here:
https://brainly.com/question/16945643
#SPJ11
Where does a asymmetric multiprocessing scheduler run?
An asymmetric multiprocessing scheduler typically runs on the operating system kernel of the primary processing unit.
This scheduler is responsible for distributing tasks to the different processing units in the system, which may have varying capabilities and resource availability. The scheduler must take into account the workload and capabilities of each processing unit in order to optimize system performance and ensure that tasks are completed efficiently. Overall, the goal of the asymmetric multiprocessing scheduler is to maximize the utilization of available resources while minimizing delays and bottlenecks in the system.
An asymmetric multiprocessing scheduler runs on the master processor in an asymmetric multiprocessing system. This type of scheduler is responsible for managing tasks and resources across multiple processors, with the master processor handling the scheduling and coordination, while the other processors execute the assigned tasks.
To know more about operating system, click here:
https://brainly.com/question/30778007
#SPJ11
A typical source rock of oil, which started out as mud in which dead organic matter settled, isChoose one:A. shale.B. granite.C. conglomerate.D. sandstone.
Shale is the primary source rock for the vast majority of the world's oil and natural gas reserves.
A typical source rock of oil, which started out as mud in which dead organic matter settled, is shale. Shale is a sedimentary rock that is formed from the accumulation of clay and other fine-grained sedimentary particles. Over time, the accumulation of dead organic matter, such as plankton and algae, is buried by the sedimentary layers and undergoes a process of heat and pressure called diagenesis, which eventually transforms the organic matter into hydrocarbons such as oil and natural gas.
Learn more about rock here:
https://brainly.com/question/17137899
#SPJ11
The collections framework algorithms are ___, i.e., each of these algorithms can operate on objects that offer given interfaces without concern to the underlying implementations
The collections framework algorithms are implementation-agnostic, i.e., each of these algorithms can operate on objects that offer given interfaces without concern to the underlying implementations.
This allows for flexibility and adaptability when working with different types of collections. The collections framework algorithms are interface-based, i.e., each of these algorithms can operate on objects that offer given interfaces without concern to the underlying implementations. This means that the algorithms are designed to work with any class that implements the required interface, regardless of how the class is implemented internally. This allows for greater flexibility and reusability of code within the collections framework.
Learn More about framework here :-
https://brainly.com/question/28991812
#SPJ11
Life safety branch of the emergency systemshall supply power for all of the following except: ________________.
517.32
The Life safety branch of the emergency system shall supply power for all of the following except non-emergency loads. Non-emergency loads include equipment and appliances that are not essential for life safety, such as lighting for non-essential areas, heating and cooling systems, and other non-essential equipment.
The Life safety branch is critical to ensure that essential life safety systems such as emergency lighting, fire alarms, and communication systems remain operational during an emergency or power outage. It is important to note that the Life safety branch must be designed and installed according to specific codes and standards to ensure its reliability and functionality.
Therefore, it is important to consult with a qualified electrical engineer or contractor to ensure compliance with the applicable regulations and guidelines.
Learn more about power here : brainly.in/question/1888377
#SPJ11
How many 30-pin SIMMs are installed in one bank?
The number of 30-pin SIMMs installed in one bank can vary from 2 to 8, depending on the size of the individual SIMMs and the configuration of the memory bank.
72-pin SIMMs, the number of 30-pin SIMMs installed in one bank depends on the type of SIMM and the memory controller of the computer.
30-pin SIMMs were used in older computers, such as the first generations of Macintosh computers and some IBM PCs.
SIMMs typically came in sizes of 256KB, 512KB, 1MB, 2MB, 4MB, and 8MB.
A bank of memory using 256KB or 512KB SIMMs would typically have 8 slots, whereas banks of 1MB and 2MB SIMMs would have 4 slots.
Banks using 4MB and 8MB SIMMs would have 2 slots.
It is worth noting that 30-pin SIMMs are no longer commonly used in modern computers.
For similar questions on bank
https://brainly.com/question/14905714
#SPJ11